Barcode Problems -Lamb Seasoning

This GS1-128 barcode contains the correct data, but the very poor method of printing has caused multiple problems. The bars are too light,too thin and contain a number of light bands. Also the barcode has been printed bellow the minimum size specified for this type of code.

REA Scancheck 3
Barcode verification reports
created with REA Scancheck 3
Problem Page
TransWin32, Version 1.0.9.10

Isis Integration Ltd 6 Cantelupe Mews, Cantelupe Road East Grinstead, RH19 3BG
Barcode Problem GS1-128
Operator: SC3 User
         
Aperture: 10 mil, 0.25 mm
Wavelength: Laser 670 nm
Unit: Micrometer [µm]
Date: 7/21/2008 3:11:49PM
Device: REA ScanCheck 3 (V1.0.9.11)
Serial Number: 0030.207.105-03096-8
Symbology: GS1-128
Code Content: (01)05000225007094(15)100306(10)L8066
         
User comment:
Lamb Seasoning:
GS1 Business comment:
Bars to light in colour causing lack of contrast between bars and spaces, hence Modulation failure.
Magnification only 31% (0.315). Minimum for General Distribution is 50% (0.495), hence faiure on Decode.
Thin bars, hence Decodability failure.
Many light bands in bars seen as Defects.
Evaluation: ISO/IEC 15416, ISO/IEC 15417, GS1 General Specification
Measurements: 3 Measurements of 3
Symbol: Fail 0.0/10/670
List of errors:
01) Error Element determination
02) Error Element determination
03) Error Element determination
04) Error Modulation too low, actual: 32%, Min Value: 50%
05) Error Global threshold violation
06) Error Defects too large, actual: 32%, Max Value: 25%
07) Error Decodability too low, actual: 19%, Min Value: 37%
08) Warning PCS-EC too low, actual: 0.30, Min Value: 0.75
09) Warning PCS-EC Rb too high, actual: 48%, Max Value: 34%
10) Warning Bar too narrow, actual: -385%, Min Value: -100%
11) Warning Space too large, actual: 370%, Max Value: 100%
12) Warning Mean too small, actual: -110%, Min Value: -100%
13) Warning E-Value too small, actual: -245%, Min Value: -100%
14) Warning E-Value too large, actual: 275%, Max Value: 100%
15) Warning P-Value too small, actual: -490%, Min Value: -100%
16) Warning P-Value too large, actual: 450%, Max Value: 100%
17) Error Z-Module too small, actual: 315, Min Value: 495
Selected Grade 2 (1.5)      
Overall symbol grade 0.0      
           
Scan: 1 2 3 [Average]  
           
Decode: 0 0 0 [0.0]  
Edge Contrast: 4 4 4 [4.0 (21%)]  
Symbol Contrast: 3 3 3 [3.0 (64%)]  
Modulation 0 0 0 [0.0 (32%)]  
Rmin/Rmax: 4 4 4 [4.0 (21%)]  
Defects 0 1 1 [0.6 (30%)]  
Decodability 0 0 0 [0.0 (19%)]  
OPTIONAL PARAMETERS          
           
Z-Module 0 0 0 [0.0 (315)]  
           
SRP grade 0 0 0    
Overall symbol grade       0.0  